​佳 盼 塑 胶

JIA PAN  SU JIAO

销售热线:13711820929

/ Product details

产品详情
产品分类

/ classification

PBT 6129 NC010 高粘度,挤出和注塑级

PBT 6129 NC010 高粘度,挤出和注塑级

Crastin 6129 is an unreinforced, high viscosity polybutylene terephthalate for extrusion and injection moulding.
0.00
0.00
  
Crastin 6129 is an unreinforced, high viscosity polybutylene terephthalate for extrusion and injection moulding.

Crastin® 6129 NC010 | PBT THERMOPLASTIC POLYESTER RESIN

 

Regional Availability

Europe, Near East/Africa

 

Processing

Injection Moulding, Profile Extrusion, Sheet Extrusion, Other Extrusion, Coatable

 

Delivery form

Pellets

 

Product Text

Common features of Crastin® thermoplastic polyester resin include mechanical and physical properties such as stiffness and toughness, heat resistance, friction and wear resistance, excellent surface finishes and good colourability. Crastin® thermoplastic polyester resin has excellent electrical insulation characteristics and high arc-resistant grades are available. Many flame retardant grades have UL recognition (class V-0). Crastin® thermoplastic polyester resin typically has high chemical and heat ageing resistance.

 

The good melt stability of Crastin® thermoplastic polyester resin normally enables the recycling of properly handled production waste. If recycling is not possible, DuPont recommends, as the preferred option, incineration with energy recovery (24 kJ/g of base polymer) in appropriately equipped installations. For disposal, local regulations have to be observed.

 

Crastin® thermoplastic polyester resin typically is used in demanding applications in the electronics, electrical, automotive, mechanical engineering, chemical, domestic appliances and sporting goods industry.

 

Crastin® 6129 is an unreinforced, high viscosity polybutylene terephthalate for extrusion and injection moulding.

 

Injection molding

PREPROCESSING

Drying recommended = Yes

Drying temperature = 110-130

Drying time, dehumidified dryer = 2-4 h

Processing moisture content = <0.04 %

 

PROCESSING

Melt temperature optimum = 250

Melt temperature range = 240-260

Mould temperature optimum = 80

Mould temperature range = 30-130

 

POSTPROCESSING

Profile extrusion

PREPROCESSING

Drying recommended = Yes

Drying temperature = 110-130

Drying time, dehumidified dryer = 2-4 h

Processing moisture content = <0.04 %

 

PROCESSING

Melt temperature optimum = 250

Melt temperature range = 240-260

 

PROPERTIES

Rheological properties

Value

Unit

Test Standard

Melt mass-flow rate

10

g/10min

ISO 1133

Temperature

250

ISO 1133

Load

2.16

kg

ISO 1133

Moulding shrinkage,parallel

1.7

%

ISO 294-4,2577

Moulding shrinkage,normal

1.5

%

ISO 294-4,2577

Mechanical properties

Value

Unit

Test Standard

Tensile Modulus

2600

MPa

ISO 527-1/-2

Yield stress

58

MPa

ISO 527-1/-2

Yield strain

5

%

ISO 527-1/-2

Nominal strain at break

>50

%

ISO 527-1/-2

Tensile creep modulus,1h

2500

MPa

ISO 899-1

Tensile creep modulus,1000h

1800

MPa

ISO 899-1

Charpy impact strength,23

N

kJ/m²

ISO 179/1eU

Charpy impact strength,-30

N

kJ/m²

ISO 179/1eU

Charpy notched impact strength,23

5.5

kJ/m²

ISO 179/1eA

Charpy notched impact strength,-30

4

kJ/m²

ISO 179/1eA

Thermal properties

Value

Unit

Test Standard

Melting temperature,10/min

225

ISO 11357-1/-3

Temp. of deflection under load,1.8 MPa

50

ISO 75-1/-2

Temp. of deflection under load,0.45 MPa

115

ISO 75-1/-2

Vicat softening temperature,50/h,50N

175

ISO 306

Coeff. of linear therm. expansion,parallel

130

E-6/K

ISO 11359-1/-2

Coeff. of linear therm. expansion,normal

130

E-6/K

ISO 11359-1/-2

Flammability

Value

Unit

Test Standard

Burning Behav. at 1.5 mm nom. thickn.

HB

class

IEC 60695-11-10

Thickness tested

1.5

mm

IEC 60695-11-10

UL recognition

UL

-

-

Burning Behav. at thickness h

HB

class

IEC 60695-11-10

Thickness tested

0.9

mm

IEC 60695-11-10

UL recognition

UL

-

-

Oxygen index

22

%

ISO 4589-1/-2

Electrical properties

Value

Unit

Test Standard

Relative permittivity,1MHz

3.2

-

IEC 60250

Dissipation factor,1MHz

200

E-4

IEC 60250

Volume resistivity

>1E13

Ohm*m

IEC 60093

Surface resistivity

1E+12

Ohm

IEC 60093

Electric strength

26

kV/mm

IEC 60243-1

Comparative tracking index

600

-

IEC 60112

Other properties

Value

Unit

Test Standard

Water absorption,2mm

0.4

%

Sim. to ISO 62

Humidity absorption,2mm

0.2

%

Sim. to ISO 62

Density

1320

kg/m³

ISO 1183

Material specific properties

Value

Unit

Test Standard

Viscosity number

150

cm³/g

ISO 307,1157,1628

Rheological calc. properties

Value

Unit

Test Standard

Density of melt

1120

kg/m³

-

Thermal conductivity of melt

0.25

W/(m K)

-

Spec. heat capacity melt

2090

J/(kg K)

-

Ejection temperature

150

-

VDA Properties

Value

Unit

Test Standard

Burning rate,Thickness 1 mm

21

mm/min

ISO 3795 (FMVSS 302)

 

Chemical Media Resistance

Acids

√ Acetic Acid (5% by mass) (23)

√ Citric Acid solution (10% by mass) (23)

√ Lactic Acid (10% by mass) (23)

× Hydrochloric Acid (36% by mass) (23)

× Nitric Acid (40% by mass) (23)

× Sulfuric Acid (38% by mass) (23)

× Sulfuric Acid (5% by mass) (23)

× Chromic Acid solution (40% by mass) (23)

Bases

× Sodium Hydroxide solution (35% by mass) (23)

√ Sodium Hydroxide solution (1% by mass) (23)

√ Ammonium Hydroxide solution (10% by mass) (23)

Alcohols

√ Isopropyl alcohol (23)

√ Methanol (23)

√ Ethanol (23)

Hydrocarbons

√ n-Hexane (23)

√ Toluene (23)

√ iso-Octane (23)

Ketones

√ Acetone (23)

Ethers

√ Diethyl ether (23)

Mineral oils

√ SAE 10W40 multigrade motor oil (23)

× SAE 10W40 multigrade motor oil (130)

× SAE 80/90 hypoid-gear oil (130)

√ Insulating Oil (23)

Standard Fuels

× ISO 1817 Liquid 1 (60)

× ISO 1817 Liquid 2 (60)

× ISO 1817 Liquid 3 (60)

× ISO 1817 Liquid 4 (60)

√ Standard fuel without alcohol (pref. ISO 1817 Liquid C) (23)

√ Standard fuel with alcohol (pref. ISO 1817 Liquid 4) (23)

√ Diesel fuel (pref. ISO 1817 Liquid F) (23)

√ Diesel fuel (pref. ISO 1817 Liquid F) (90)

× Diesel fuel (pref. ISO 1817 Liquid F) (>90)

Salt solutions

√ Sodium Chloride solution (10% by mass) (23)

√ Sodium Hypochlorite solution (10% by mass) (23)

√ Sodium Carbonate solution (20% by mass) (23)

√ Sodium Carbonate solution (2% by mass) (23)

√ Zinc Chloride solution (50% by mass) (23)

Other

√ Ethyl Acetate (23)

× Hydrogen peroxide (23)

× DOT No. 4 Brake fluid (130)

× Ethylene Glycol (50% by mass) in water (108)

√ 1% nonylphenoxy-polyethyleneoxy ethanol in water (23)

√ 50% Oleic acid + 50% Olive Oil (23)

√ Water (23)

× Water (90)

√ Phenol solution (5% by mass) (23)

 

Symbols used:

√ possibly resistant

Defined as: Supplier has sufficient indication that contact with chemical can be potentially accepted under the intended use conditions and expected service life. Criteria for assessment have to be indicated (e.g. surface aspect, volume change, property change).

 

× not recommended - see explanation

Defined as: Not recommended for general use. However, short-term exposure under certain restricted conditions could be acceptable (e.g. fast cleaning with thorough rinsing, spills, wiping, vapor exposure).

 

销售热线:13622665826